{"product_id":"omron-by35s","title":"OMRON BY35S [UPS (constant commercial power supply\/sine wave output) 350VA\/210W]","description":"\u003cp\u003e\u003cstrong\u003eOMRON BY35S\u003c\/strong\u003e is a 350VA \/ 210W standby (offline) UPS made for the Japanese market. It is rated for AC100V only, so outside Japan it needs a step-down transformer or a 100V supply. The replacement battery is the \u003ca href=\"\/products\/omron-byb50s\"\u003eBYB50S\u003c\/a\u003e.\u003c\/p\u003e\u003cp\u003eJapan-domestic UPS units like the BY35S are often built into Japanese-made machines — semiconductor and SMT lines, inspection systems, machine tools and lab analyzers. Replacing a failed unit with the same model avoids rewiring and re-qualification. We ship genuine new units from Tokyo by FedEx; tell us your country and we will confirm voltage and plug before you order.\u003c\/p\u003e\u003ch3\u003eQuick facts for international buyers\u003c\/h3\u003e\u003ctable style=\"border-collapse:collapse;width:100%;margin-bottom:18px\" border=\"1\"\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;padding:6px 10px;width:34%\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px\"\u003eBY35S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;padding:6px 10px;width:34%\"\u003eUsable on 110–120V mains\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px\"\u003eNo — this is a Japan-domestic model rated for AC100V only. Outside Japan, use it behind a step-down transformer that supplies 100V, or inside Japanese equipment that already provides 100V.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;padding:6px 10px;width:34%\"\u003eInput voltage\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px\"\u003eAC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;padding:6px 10px;width:34%\"\u003eInput plug \/ connection\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px\"\u003eNEMA 5-15P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;padding:6px 10px;width:34%\"\u003eOutput outlets\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px\"\u003eNEMA 5-15R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;padding:6px 10px;width:34%\"\u003eReplacement battery\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px\"\u003e\u003ca href=\"\/products\/omron-byb50s\"\u003eBYB50S\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;padding:6px 10px;width:34%\"\u003eBattery type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px\"\u003eSealed lead-acid (VRLA), non-spillable. Expected life: 4–5 years at 20°C.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;padding:6px 10px;width:34%\"\u003eMarket\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px\"\u003eGenuine new product for the Japanese market. Manuals and labels are in Japanese.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;padding:6px 10px;width:34%\"\u003eNeed help?\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px\"\u003eSee the \u003ca href=\"\/pages\/ups-battery-cross-reference\"\u003eOMRON \/ Mitsubishi UPS battery cross-reference\u003c\/a\u003e, or contact us with your UPS model and country and we will confirm compatibility before you order.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eManufacturer specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eUPS topology\u003c\/th\u003e\n\u003ctd\u003eStandby (offline)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eForm factor\u003c\/th\u003e\n\u003ctd\u003eVertical or horizontal placement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated input voltage\u003c\/th\u003e\n\u003ctd\u003eAC100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated input frequency\u003c\/th\u003e\n\u003ctd\u003e50\/60Hz±4Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of input phases\u003c\/th\u003e\n\u003ctd\u003eSingle-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput plug\u003c\/th\u003e\n\u003ctd\u003eNEMA5-15P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated output voltage\u003c\/th\u003e\n\u003ctd\u003eAC100V±10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated output frequency\u003c\/th\u003e\n\u003ctd\u003e50\/60Hz±1Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of output phases\u003c\/th\u003e\n\u003ctd\u003eSingle-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput outlet type\u003c\/th\u003e\n\u003ctd\u003eNEMA5-15R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBackup outlets\u003c\/th\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNon-backup outlets (surge only)\u003c\/th\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower consumption (normal\/max)\u003c\/th\u003e\n\u003ctd\u003e30W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum output capacity (W)\u003c\/th\u003e\n\u003ctd\u003e210W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum output capacity (VA)\u003c\/th\u003e\n\u003ctd\u003e350VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBackup time (at full load)\u003c\/th\u003e\n\u003ctd\u003e5 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput voltage during battery operation\u003c\/th\u003e\n\u003ctd\u003e100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput frequency during battery operation\u003c\/th\u003e\n\u003ctd\u003e50\/60Hz±1Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput waveform during battery operation\u003c\/th\u003e\n\u003ctd\u003eSine wave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTransfer time\u003c\/th\u003e\n\u003ctd\u003eWithin 10msec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBattery type\u003c\/th\u003e\n\u003ctd\u003eSealed lead-acid (VRLA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of batteries\u003c\/th\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCharging time\u003c\/th\u003e\n\u003ctd\u003e12 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBundled power management software\u003c\/th\u003e\n\u003ctd\u003eYes (PowerAct Pro, UPS Service Driver, UPS Power Manager)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSoftware OS support\u003c\/th\u003e\n\u003ctd\u003eWindows\/Linux\/Mac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSurge function\u003c\/th\u003e\n\u003ctd\u003eYes – power-line noise and lightning surge protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety standards\u003c\/th\u003e\n\u003ctd\u003eVCCI Type B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e92(W)×285(D)×165(H)mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e4.5kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRemarks\u003c\/th\u003e\n\u003ctd\u003e3-year warranty (with 1-year battery free service)\/power factor correction (PFC) built-in power supply\/compact\/low price\/long-life battery (4 to 5 years) (user replaceable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRoHS Directive\u003c\/th\u003e\n\u003ctd\u003eCorrespondence\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e","brand":"OMRON","offers":[{"title":"Default Title","offer_id":43636273545454,"sku":"BY35S","price":164.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0618\/1424\/3566\/products\/00189029_01.jpg?v=1686877972","url":"https:\/\/store.asunite.net\/products\/omron-by35s","provider":"Asunite Store Japan","version":"1.0","type":"link"}