OMRON
Preset counter/tachometer H7CC-A seriesH7CC-AWS
Regular price
$141.96 USD
Regular price
$149.44 USD
Sale price
$141.96 USD
Unit price
/
per
Pursuing "easy -to -understand and easy -to -readability".
H7cc has realized a new value that contributes to reduction of conservation/work man -hours by visualization of the replacement time and improving visibility and operability.
Implemented an LED that guides intuition operation.
Insulation and input between the power supply and the wiring design more easily.
No consideration for grounding or turning circuit is required.
Replacement timing prevention of post -conservation and maintenance man -hours
Calculation tools to easily calculate the replacement time
Withstand voltage |
Charging metal part and non-charging metal part: AC2000V 50/60Hz 1min Between power and input circuit: AC2000V 50/60Hz 1min (Other than shape H7cc- □ D □) (AC24V/DC12 ~48V type is AC1,500V) Control output and power supply, input circuit: AC1,500V 50/60Hz 1min (shape H7cc- □ SD □), AC2000V 50/60Hz 1min (shape H7cc- □ SD □Other) Non -continuous contact: AC1,000V 50/60Hz 1min |
---|---|
Input method |
Voltage (NPN) input/voltage (PNP) Input switching [Voltage input] Imped by short circuit: 1 kΩ or less (0Ω flow current about 12 mA), short circuit residual voltage: 3V or less, open impedance.: 100kΩ or more |
function |
1 -stage preset counter, 2 -stage preset counter, total pre -set counter, batch counter, dual counter, twin counter, tachometer/8 times/16 times |
input signal |
CP1, CP2, reset 1, reset 2 [Pulse width measurement] 30ms, 1 input mode: 0.2ms, 1 input mode: 0.4ms |
life |
Mechanical life: 10 million or more Electrical life: 100,000 or more (AC250V 3A resistance load, surrounding temperature conditions: 23 ° C) |
Measurement range |
[Passive measurement] 0.001Hz to 30.00Hz, 1 input mode: 0.001Hz to 10kHz, 1 input mode: 0.01-5kHz [Pulse width measurement] 0.030-999999S, 1 input mode: 0.0002999999S, 1 input mode time: 0.0004-999999S |
Impulse voltage (v) |
between power supply terminals: 6.0k (AC24V/DC12 to 48V type is 1.0 kV) |
Output mode |
[Rated] N, C, C, R, K-1, P, P, Q, A, K-2, D, L, H [Tachometer] Input mode = 2 Other than input measurementsLower/range/maximum/lower limit, 2 input independent measurement: Upper/lower limit |
Input mode |
[Rated] Addition (UP), subtraction (Down), addition (Up/Down a (command input), Up/Down B (individual input), Up/Down C (phase difference entry)),Up/Down D (command entry), Up/Down E (individual input), Up/Down f (Phase difference input)Absolute ratio input, 2 input and error ratio can be selected from input |
Sampling cycle (MS) |
[Passive measurement] minimum 200ms, minimum 200 ms/continuous (minimum 10 ms interval) Switching [Pulse width measurement] continuous (minimum 10 ms interval) |