MITSUBISHI
Mitsubishi Electric FW-A10H-1.0K [FREQUPS A Series (Line Interactive) 1000VA/700W Long life]
Regular price
$668.33 USD
Regular price
$703.51 USD
Sale price
$668.33 USD
Unit price
/
per
Uses a long-life battery (expected life: 5 years, ambient temperature: 20°C). Supports a wide range of input voltages from AC 81 V to 124 V by performing voltage correction with the AVR function. Protects backup equipment by preventing lightning surges, noise, etc. The operation part of the UPS is made into a wired remote controller and connected to the main UPS with a cable. It is easy to check the operating status under the desk, in the rack, or out of sight. With the hot-swap method, the front panel can be opened and closed even while the UPS is in operation. The battery can be easily replaced even when the UPS is in operation. With RS232C connector and USB connector
Driving method | Line interactive method |
---|---|
Chassis | Stationary |
Rated input voltage | AC81V~124V + 3V |
Rated input frequency | 50Hz/60Hz ±10% |
Number of input phases | Single-phase two-wire system (with ground) |
Input outlet shape | NEMA5-15R |
Rated output voltage | AC100V 5% |
Rated output frequency | 50Hz/60Hz ±0.8% |
Number of output phases | Single-phase two-wire system (with ground) |
Outlet shape | 2P15A outlet with single-phase grounding pole |
Number of output outlets (backup): 6 *Time lag switch on/off function (OUTPUT 1: 4, OUTPUT 2: 2) | |
Number of output outlets (through) | 0 |
Power Consumption (Normal/Maximum) | 50W |
Maximum Output Capacity (W) | 700W |
Maximum output capacity (VA) | 1000VA |
Backup time (at full load) | 5 minutes |
Output voltage during battery operation | 100V |
Output frequency during battery operation | 50/60Hz ± 0.8% |
Output waveform during battery operation | Low distortion sine wave |
Time to switch to battery | Within 4 ms |
Battery type | Compact sealed lead battery (expected life: 5 years, ambient temperature: 20°C) hot-swappable/maintenance is easy with battery and fan full-surface removal |
Number of batteries | one |
Charging time | Within 5 hours |
Power management software (attached software) | None (sold separately) *Simple management software can be downloaded from the Mitsubishi Electric website |
Power management software compatible OS | Sold separately (FREQSHIP) Windows2000/XP/Sever2003/Vista/solaris10/HP-UX/AIX/RedHat Linux/SUSELinux/MiracleLinux/TurboLinux, etc. |
Surge function | Yes (4000V peak 1.2μS (rising) × 50μS (falling) voltage is applied between the main circuit and ground and between the main circuit lines (between R and S), and it has been confirmed that there is no problem such as damage to the UPS. ) |
Safety standards | VCCI class A |
Body size (H×W×D) | 220×170×440mm |
body weight | 21kg |
Remarks: Battery output voltage: AC100V 5% | |
Asbestos | not included |
RoHS Directive | Compliant (built-in battery is not subject to RoHS Directive) |