Skip to product information
1 of 1

MITSUBISHI

Mitsubishi Electric FW-S10-0.7K [FREQUPS S series (constant inverter) 700VA/560W]

Regular price $691.01 USD
Regular price $727.38 USD Sale price $691.01 USD
Sale Sold out
Tax included. Shipping calculated at checkout.

Uses a long-life battery (expected life: 5 years, ambient temperature: 20°C). FA model that brings peace of mind, ideal for power supply at manufacturing sites. Output voltage can be freely controlled! Can be set between 100 V and 120 V with a single 1 V. Wide range of input voltages Compatible with AC85V to 144V. Equipped with a UPS soft start function that gradually increases the output voltage to supply power to the load when the UPS starts up. Easy maintenance for replacing the battery cooling fan. Can be installed horizontally.



Driving method Constant inverter power supply system
Chassis Stationary type (horizontal installation possible)
Rated input voltage AC85-144V
Rated input frequency 47.5Hz to 63Hz
Number of input phases Single-phase two-wire system (terminal block)
Input outlet shape M4 terminal block
Rated output voltage 100-120V±2%
Rated output frequency Synchronization mode Synchronized with input frequency/Fixed mode 50Hz/60Hz ±0.5% (50Hz/60Hz can be selected arbitrarily) (factory default sync mode)
Number of output phases Single-phase two-wire
Power Consumption (Normal/Maximum) 98W
Maximum Output Capacity (W) 560W
Maximum output capacity (VA) 700VA
Backup time (at full load) 4 minutes
Output voltage during battery operation 100V
Output frequency during battery operation Synchronization mode Synchronized with input frequency/Fixed mode 50Hz/60Hz ±0.5% (50Hz/60Hz can be selected arbitrarily) (factory default sync mode)
Output waveform during battery operation sine wave
Time to switch to battery Uninterrupted
Battery type Small sealed lead battery (expected life: 5 years, ambient temperature: 20°C)
Number of batteries one
Charging time 8 hours
Power management software (attached software) None (sold separately) *Simple management software can be downloaded from Mitsubishi Electric's website
Power management software compatible OS Microsoft Windows/Linux/UNIX
Surge function Yes (4000V peak 1.2μS (rising) × 50μS (falling) voltage is applied between the main circuit and ground and between the main circuit lines (between R and S), and it has been confirmed that there is no problem such as damage to the UPS. )
Safety standards VCCI class A
Body size (H×W×D) 255X155X415mm
body weight 15kg
Remarks Battery output voltage AC100V ±2%